[. . . ] English User's Manual FlexScan F730 Color Display Monitor â CONTENTS PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Controls & Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 1-1 Connecting the Monitor to the PC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] · Do your part to conserve energy, turn off the monitor when your finished using it. Complete energy use can only be stopped by disconnecting the monitor from the power supply. · When the monitor is in a power saving mode, the optional EIZO i·Sound speaker unit will turn off. · Off Timer will work while PowerManager is active, but there will be no advance notice before the monitor's power switches off. The acronym VESA stands for "Video Electronics Standards Association, " and DPMS stands for "Display Power Management Signaling. " DPMS is a communication standard that PCs and graphics boards use to implement power savings at the monitor side. "ENERGY STAR" is a set of power saving guidelines issued by the U. S. The guidelines apply to PC systems and peripherals. As an ENERGY STAR® Partner, Eizo Nanao Corporation has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. Set-up Procedure 1) First, make the appropriate settings for the PC. 2) Select VESA DPMS icon in the ScreenManager's PowerManager menu. Power saving method of VESA DPMS and the monitor VESA DPMS utilizes four signals: ON, STAND-BY, SUSPEND, and OFF. The monitor detects these signals from the graphics board and executes powersaving accordingly, as shown in the table below. Signal ON STAND-BY SUSPEND OFF Screen Operation Blank Blank (Mode 1) Blank (Mode 2) LED Green Green Flashing green Yellow Power consumption 120 W (normal) 80% of normal less than 10 W less than 3 W 16 2 SCREEN ADJUSTMENT Function Off Timer What is Off Timer?The Off Timer function allows the user to set the time in which the monitor will be in operation, called the "On Period" and automatically shifts the operation into the "Off Timer Mode" when the set "On Period" expires. The energy consumption of the monitor in the "Off Timer Mode" is as low as the one of the monitor in "PowerManager Mode 2" although no setting PC to operate the Off Timer function is required. E Set-up Procedure 1) Select the "Off Timer" icon. 2) Press the right/left key to adjust how long (0 to 23 hours) the monitor should be in the "On Period". Advance notice (LED flashing green) will be given 15 minutes before the monitor automatically enters the "Off Timer Mode". To Delay Entering the "Off Timer Mode" To delay entering the "Off Timer Mode", press any keys on the front panel located to the left of the power switch during the "Advance notice Mode". Delayed entrance into the "Off Timer Mode" can be extended as many times as desired. Function Signal Filter This monitor provides signal filter adjustments according to the characteristics of each graphics board for displaying the image properly. If the characteristics of the graphics board does not match those of the monitor, the characters and images displayed may have a slight shadow on their right side (refer to figure on the left). If these phenomenon is noticeable, use the "Signal Filter" function. adjusts: Video Level Video Level Set the video level to adapt the output level of the computer or the graphics board. Menu Position adjusts: Menu Position 2 SCREEN ADJUSTMENT 17 Function Reset resets all the settings. - Default settings are as follows: · Contrast/Brightness:100 % /50 % · Moiré (Horizontal) (Vertical) · Color: 9300 K · PowerManager VESA DPMS Off Timer · Signal Filter Mode 1 · Video Level 0. 7 V 0% 0% On Disable 2-3. Shortcut Keys Before entering the ScreenManager, brightness and contrast can be adjusted directly by moving the Control pad. To record the new setting and exit the ScreenManager, press the Enter key. [. . . ] The relevant TCO'99 requirement states that batteries may not contain any mercury. It also demands that mercury is not present in any of the electrical or electronics components associated with the labelled unit. CFCs (freons) The relevant TCO'99 requirement states that neither CFCs nor HCFCs may be used during the manufacture and assembly of the product. CFCs break down ozone and thereby damage the ozone layer in the stratosphere, causing increased reception on earth of ultraviolet light with e. g. increased risks of skin cancer (malignant melanoma) as a consequence. Lead** Lead can be found in picture tubes, display screens, solders and capacitors. [. . . ]